Mvci Driver For Toyota Windows 10 64 Bit
- Techstream and MVCI on 64bit Windows 8.1 & Win 10 works! January 4, 2016 sales Car diagnostic tool 0 Especially download Windows XP system for Techstream interface (suggested by obdexpress technicians), just to shut off the DRL’S. Nov 22, 2016 (Solution) Mini VCI + Toyota TIS Techstream 8.x on Windows 7/8 64-bit.
- Mini Vci J2534 Driver For Windows 10 64 Bit Mini Vci J2534 Driver Download Mini Vci 64 Bit Drivers Xhorse Mvci Driver Windows 10. Connect the Mini VCI cable and run the application FirmwareUpdateTool and click the Device Info button. If your device is showing as connected then it is ready to be used with Techstream.
Test version: Techstrea V10.20.030 Test cable: XHorse MVCI cable (Xhorse MINI VCI cable with firmware 2.0.4 should work as well) This manual is made for 64-bit editions of Windows. How to install Techstream V10.10.018 into Windows 7/8 64bit OS. TechstreamUpdateV8.10.021 - MVCI Driver for TOYOTA - TIS KEY 3. Now open WinRAR again.
How to setup mini vci with Techstream on 64bit computer
Posted by:mistan
Following info is adapted from here. Another site with a similar instruction. If you do not have the software and drivers, a vender from amazon provides a link for download.
Mvci Driver For Toyota Windows 10 64 Bit Download
TIS Techstream V10 Setup Instruction ( !!! for 64 bit system !!! ) :
- The Techstream version 12* and above should be compatible with Windows 10 64 bit system.
- Installed and follow through instruction.
- Start Techstream and input Area, then shutdown
- copy Mainmenu.exe in Bin folder under installation folder.
- start Techstream and input registration code.
- unzip the MCVIDriver.msi, move the contents under “C:Program Files (x86)XHorse ElectronicsMVCI Driver for TOYOTA TIS”.
- plug in mini VCI cable.
- Open the Device Manager the device should be loaded. If not, right click each failing device, select Install Driver, then ”Browse my Computer” and locate to “C:Program Files (x86)XHorse ElectronicsMVCI Driver for TOYOTA TIS” (enable the ”include subfolders” flag). Click ”Next” and wait until drivers are installed. You should now see two new devices: ”Universal Serial Bus ControllersUSB Serial Converte” and ”Ports (COM & LPT)USB Serial Port (COMx)”.
- Run the FirmwareUpdateTool.exe from the “C:Program Files (x86)XHorse ElectronicsMVCI Driver for TOYOTA TIS”. Click ”Device Info”, You should see the ”Device connected” screen.
Windows 10 Download
- Now install Techstream software using “Techstream_Setup_V12…exe” on our software CD
Software Registration: copy the two *.ini files in ”Registration” folder to “C:Program Files (x86)Toyota DiagnosticsTechstreamEnv
Attention: It’s C:Program Files (x86) not C:Program Files , BIG DIFFERENCE !!!
- Registry Hack: Run the mvci-64bit.reg file (here for download) to modify the registry for Techstream to recognize MINI-VCI under Windows x64
- Run Techstream software. Go to Setup | VIM Select menu and select the ”XHorse — MVCI”
- Connect Mini VCI cable to your car‘s OBDII interface, turn ignition on, then click ”Connect to Vehicle” in Techstream. Wait. Then wait again. If everything works, you will be prompted to confirm car year/model after which you’ll get to the diagnostic interface.
Important Note:
- DO NOT change the “User Type” when you will run your TIS Techstream for 1st time! LEAVE IT with the Default option! “Official” Dealer/Repairer with other words…
- in [ VIM Select ] option, please select the [ Xhorse — MVCI ], not [ TIS Techstream VIM ]
- If you get the following reminder while using the program:
Windows 10
— — — — — — — — — — — — — — — — — — — — — –
Register Techstream Software (S314–03)
Network connection is unavailable. A network connection is required to use Techstream software.
You can only connect 29 more times without a network connection before software registration is required.
Mvci Driver For Toyota Windows 10 64 Bit Download
— — — — — — — — — — — — — — — — — — — — —
You can reset that as following steps:
Go to C:Program FilesToyota DiagnosticsTechstreamEnv and find ”IT3usercustom.ini” file and look for ”Connectioncount=1” or what ever number of times you tried and just delete ”connectioncount=1”. Click save and you should be reseted back to 30
JAN